{"id":1960,"date":"2024-12-31T18:24:34","date_gmt":"2024-12-31T17:24:34","guid":{"rendered":"https:\/\/polgec.igf.edu.pl\/?page_id=1960"},"modified":"2026-03-20T11:00:59","modified_gmt":"2026-03-20T10:00:59","slug":"exhibition-apparatus","status":"publish","type":"page","link":"https:\/\/polgec.igf.edu.pl\/index.php\/exhibition-apparatus\/","title":{"rendered":"Exhibition &#8211; Apparatus"},"content":{"rendered":"\n<p class=\"has-text-align-center\"><em>The Beginnings of Atmospheric Electricity Measurements at the Geophysical Observatory in \u015awider<\/em><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">M<strong>easurements of atmospheric potential gradient<\/strong><\/h2>\n\n\n\n<p>To measure the atmospheric electric field &#8211; or, equivalently, the electric <strong>potential gradient (PG)<\/strong> &#8211; the \u015awider team used cutting\u2011edge instruments common at leading observatories of the time.<\/p>\n\n\n\n<div class=\"wp-block-media-text is-stacked-on-mobile\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"581\" height=\"653\" src=\"https:\/\/polgec.igf.edu.pl\/wp-content\/uploads\/2026\/03\/Fig4_Inside.png\" alt=\"\" class=\"wp-image-2266 size-full\" srcset=\"https:\/\/polgec.igf.edu.pl\/wp-content\/uploads\/2026\/03\/Fig4_Inside.png 581w, https:\/\/polgec.igf.edu.pl\/wp-content\/uploads\/2026\/03\/Fig4_Inside-267x300.png 267w\" sizes=\"auto, (max-width: 581px) 100vw, 581px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p>Two Benndorf electrometers inside the atmospheric electricity house recording atmospheric electric potential gradient in \u015awider in the 1930s<\/p>\n<\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Benndorf recording electrometers<\/h2>\n\n\n\n<p>The Observatory purchased L. Castagna Benndorf recrding electrometers, precision instruments capable of detecting tiny changes in electrical potential. These devices used a system of metal quadrants and a lightweight needle immersed in a conductive solution, to translate electrical forces into movements recorded on paper charts. The traces they produced, called electrograms, show the rise and fall of the potential gradient throughout the day.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Radioactive collectors<\/h2>\n\n\n\n<p>The electrometers were connected to radioactive collectors, metal plates coated with a small amount of ionium (a thorium isotope). The radiation helped the plates reach the same electrical potential as the surrounding air, allowing highly responsive measurements of the electricity in the air.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">The atmospheric electricity house<\/h2>\n\n\n\n<p>A special building, completed in 1925, and later refurbished, housed the instruments. Holes in the walls allowed wires from outdoor collectors to run inside to the electrometers, while the surrounding open field ensured that the measurements reflected local atmospheric natural environment. Although simple, this setup allowed researchers to collect continuous, valuable data for nearly a decade.<\/p>\n\n\n\n<div style=\"height:32px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"875\" height=\"532\" data-id=\"2272\" src=\"https:\/\/polgec.igf.edu.pl\/wp-content\/uploads\/2026\/03\/Fig2_Swider_PK.png\" alt=\"\" class=\"wp-image-2272\" srcset=\"https:\/\/polgec.igf.edu.pl\/wp-content\/uploads\/2026\/03\/Fig2_Swider_PK.png 875w, https:\/\/polgec.igf.edu.pl\/wp-content\/uploads\/2026\/03\/Fig2_Swider_PK-300x182.png 300w, https:\/\/polgec.igf.edu.pl\/wp-content\/uploads\/2026\/03\/Fig2_Swider_PK-768x467.png 768w\" sizes=\"auto, (max-width: 875px) 100vw, 875px\" \/><figcaption class=\"wp-element-caption\">Side view of atmospheric electricity house<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"549\" data-id=\"2275\" src=\"https:\/\/polgec.igf.edu.pl\/wp-content\/uploads\/2026\/03\/Fig3_Benndorf-1024x549.jpg\" alt=\"\" class=\"wp-image-2275\" srcset=\"https:\/\/polgec.igf.edu.pl\/wp-content\/uploads\/2026\/03\/Fig3_Benndorf-1024x549.jpg 1024w, https:\/\/polgec.igf.edu.pl\/wp-content\/uploads\/2026\/03\/Fig3_Benndorf-300x161.jpg 300w, https:\/\/polgec.igf.edu.pl\/wp-content\/uploads\/2026\/03\/Fig3_Benndorf-768x412.jpg 768w, https:\/\/polgec.igf.edu.pl\/wp-content\/uploads\/2026\/03\/Fig3_Benndorf-1536x824.jpg 1536w, https:\/\/polgec.igf.edu.pl\/wp-content\/uploads\/2026\/03\/Fig3_Benndorf-2048x1099.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Benndorf<br>recording electrometer (1906)<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"593\" data-id=\"2278\" src=\"https:\/\/polgec.igf.edu.pl\/wp-content\/uploads\/2026\/03\/Fig5_Setup-1024x593.jpg\" alt=\"\" class=\"wp-image-2278\" srcset=\"https:\/\/polgec.igf.edu.pl\/wp-content\/uploads\/2026\/03\/Fig5_Setup-1024x593.jpg 1024w, https:\/\/polgec.igf.edu.pl\/wp-content\/uploads\/2026\/03\/Fig5_Setup-300x174.jpg 300w, https:\/\/polgec.igf.edu.pl\/wp-content\/uploads\/2026\/03\/Fig5_Setup-768x445.jpg 768w, https:\/\/polgec.igf.edu.pl\/wp-content\/uploads\/2026\/03\/Fig5_Setup-1536x889.jpg 1536w, https:\/\/polgec.igf.edu.pl\/wp-content\/uploads\/2026\/03\/Fig5_Setup-2048x1186.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">PG measurement installation at \u015awider 1929-1939<\/figcaption><\/figure>\n<\/figure>\n\n\n\n<p class=\"has-text-align-center\"><sub>Photo and diagrams installation of the measurement of the atmospheric electric potential gradient at \u015awider 1929-1939 (for more details and photo information see <a href=\"https:\/\/hgss.copernicus.org\/articles\/17\/13\/2026\/\">Odzimek 2026<\/a>).<\/sub><\/p>\n\n\n\n<div style=\"height:32px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-100 is-style-outline is-style-outline--2\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/polgec.igf.edu.pl\/index.php\/exhibition-history\/\">&lt; History<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-100 is-style-outline is-style-outline--3\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/polgec.igf.edu.pl\/index.php\/exhibition-people\/\">People &gt;<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<p><sub>Last updated 20 March 2026<\/sub><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The Beginnings of Atmospheric Electricity Measurements at the Geophysical Observatory in \u015awider Measurements of atmospheric potential gradient To measure the atmospheric electric field &#8211; or, equivalently, the electric potential gradient (PG) &#8211; the \u015awider team used cutting\u2011edge instruments common at leading observatories of the time. Two Benndorf electrometers inside the atmospheric electricity house recording atmospheric [&hellip;]<\/p>\n","protected":false},"author":13,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1960","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/polgec.igf.edu.pl\/index.php\/wp-json\/wp\/v2\/pages\/1960","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/polgec.igf.edu.pl\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/polgec.igf.edu.pl\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/polgec.igf.edu.pl\/index.php\/wp-json\/wp\/v2\/users\/13"}],"replies":[{"embeddable":true,"href":"https:\/\/polgec.igf.edu.pl\/index.php\/wp-json\/wp\/v2\/comments?post=1960"}],"version-history":[{"count":11,"href":"https:\/\/polgec.igf.edu.pl\/index.php\/wp-json\/wp\/v2\/pages\/1960\/revisions"}],"predecessor-version":[{"id":2407,"href":"https:\/\/polgec.igf.edu.pl\/index.php\/wp-json\/wp\/v2\/pages\/1960\/revisions\/2407"}],"wp:attachment":[{"href":"https:\/\/polgec.igf.edu.pl\/index.php\/wp-json\/wp\/v2\/media?parent=1960"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}